This article was translated from Japanese using AI. Read the Japanese original
Sending seconds from a cellar to the observing rooms#
Dent No. 1906 is the sidereal standard clock that entered service at the Royal Observatory, Greenwich, in 1871. It stood in the cellar of the magnetic observatory, where the temperature varied little, and sent seconds signals over wires to recording instruments and clocks around the site. Astronomer Royal George Biddell Airy conceived the design. E. Dent & Co. built it in London. No. 1906 is its serial number, and its silvered dial bears the year of manufacture, 1870. The surviving clock is held by Royal Museums Greenwich as ZAA0601.1 2 3
Sidereal time is equal to the right ascension of a celestial object making its upper transit across the observer’s meridian. For a star of known right ascension, the sidereal time of transit is therefore known. At the observatory, observers compared the actual meridian transits of reference stars with well-determined positions with their predicted times to find the error of the sidereal standard clock. William Hardy’s transit clock, used beside the telescope, had previously served as the standard. Electrical recording freed observers from needing to see the dial or hear the ticks of the standard clock. Airy took advantage of this by fixing the new clock to the north wall of the cellar and connecting it to the observing departments by wires.2 3 4
One impulse per complete pendulum oscillation#
The surviving wall clock measures 1,600 mm high, 435 mm wide and 243 mm deep. The nominal 12-inch dial shows minutes at the outer edge and seconds and 24 hours on two smaller dials in the upper half. A weight drives the four-wheel train, and Harrison maintaining power drives the train during winding. Inside the mahogany case, a thin partition separates the paths of the pendulum and the weight to reduce air disturbance as the weight descends past the pendulum bob.1 3
In Airy’s spring detent escapement, an arm linked to the pendulum lifts the detent in one direction of swing and releases the locked tooth of the escape wheel. The released tooth presses on the impulse pallet, giving energy to the pendulum, and the wheel immediately locks again against the locking jewel. On the return swing a thin passing spring flexes to let the arm through while the wheel remains locked. The escape wheel and seconds hand therefore advance one step for each complete oscillation of the pendulum, or every two clock seconds. The opposite pallet serves as a safety device that catches a tooth if the locking jewel fails to hold the wheel.2 3
Compensating for temperature and air pressure#
In trials with a mercury pendulum during manufacture, raising the room temperature made the clock temporarily lose time because the mercury warmed more slowly than the rod expanded. The chosen pendulum had an inner steel rod, a zinc tube supported at the rod’s lower end, and an outer steel tube suspended from the upper edge of the zinc tube. The zinc tube expands upwards, offsetting the downward movement of the lead bob as the steel parts expand. Openings admit air to the inside of the tubes. The crutch linking the pendulum and escapement carried two compensation bars made of steel and brass. Their inclination allowed fine adjustments to the temperature compensation. A separate threaded weight could be raised or lowered to change the rate while the pendulum kept swinging.1 2 3
Airy observed that a rise of one inch of mercury (25.4 mm) in the barometer moved the daily rate by about 0.3 seconds in the direction of losing time. Initially the change was corrected by calculation. In autumn 1873, Airy and Thomas Buckney of Dent added a magnetic compensator. A float in a mercury barometer moved a lever, raising or lowering a horseshoe magnet at its other end. Bar magnets were mounted in front of and behind the pendulum bob. As their distance from the horseshoe magnet changed, the force of attraction changed. The magnetic effect on the rate offset the tendency to gain at lower pressure. In 1893 the compensation was found to be insufficient and the device was readjusted.2 3 5
Seconds signals for recording observations#
At first the pendulum, which took one second to swing in either direction, closed the circuit by bringing two light contact springs together each time it passed through the middle. A separate contact opened the circuit once a minute, producing 59 signals per minute. In a recorder that marked observation times as dots on paper wrapped around a rotating drum, the missing dot marked the minute boundary. The standard clock’s signal operated a relay that distributed the signal to the recorder, a half-second chronometer near the eyepiece of the Great Equatorial, and other half-second clocks and audible devices on the site.2 3
A chronometer in the Computing Room ran directly from the signals. Its seconds scale had 59 divisions and its hand paused one extra second where the signal was omitted. Observatory staff used the standard clock’s error found from star observations and the comparison of the two times in the Computing Room to correct the mean solar standard clock. The mean solar time circuit sent signals to the time ball and to lines outside the observatory. Dent No. 1906 thus supported the process that turned star observations into time for distribution.2 3 4
During changes made in late 1881, a 30-tooth wheel on the escape-wheel arbor took over the operation of the contacts from the pendulum. It closed them after the pendulum had received impulse and disengaged from the train. The recorder received signals two seconds apart, and a separate contact sent a reference signal at the start of each minute. Observers subdivided the two-second intervals on the recording paper to read the times of observations.2
Repairs and replacement as the standard#
The cellar helped stabilise the temperature, but ventilation work affected the rate, and the blows from installing nearby shelving caused a sudden change. In 1895 lack of oil damaged a pivot on the escape-wheel arbor. Hardy’s clock served as standard during the repairs. Dent No. 2 was substituted during an overhaul in 1911. No. 1906 was moved to the new clock room in the Meridian Building and returned to service in December.2 6
A clock made by Cottingham on the Riefler principle took over as the sidereal standard on October 24, 1922. No. 1906 survived and appeared in an exhibition on the development of time standards at the 1951 Festival of Britain. The glazing at the top of the case and in the front door dates from alterations made for the exhibition. As of November 20, 2026, the museum catalogue listed the clock as off display.1 2 6 7
Timeline#
| Date | Event |
|---|---|
| 1869 | The Royal Observatory, Greenwich, places the order with E. Dent & Co.2 |
| 1870 | The silvered dial is engraved with the maker’s name, serial number and year.1 2 |
| May and August 1871 | Buckney installs the clock on May 25, and it enters service as the sidereal standard on August 21.2 |
| Autumn 1873 | Barometric compensation is added using a mercury barometer and magnets.2 3 |
| 1880–1881 | The clock is sent to Dent for electrical alterations, and Hardy’s clock substitutes. It returns in November 1881. The escape-wheel arbor operates the contacts to send two-second signals.2 |
| 1893 | The maintaining power is reinforced and the barometric compensation adjusted.2 |
| September–December 1911 | Overhaul and relocation. The clock returns to service in the clock room in the Meridian Building on December 4.2 6 |
| October 1922 | Cottingham’s clock takes over as the sidereal standard.6 7 |
| 1951 | The front door and top of the case are glazed and the clock is shown at the Festival of Britain in London.1 2 |
| 1974 | On loan to the National Maritime Museum and displayed in the Spencer Jones Gallery.2 |
| November 2026 | The location is confirmed in the Royal Museums Greenwich collection record ZAA0601.1 |
Related articles#
References#
- [1] Royal Museums Greenwich, “A wall mounted astronomical regulator with Airy’s spring detent escapement, manufactured by E. Dent & Co. No. 1906, c.1870”, accession no. ZAA0601. Accessed November 20, 2026.
- [2] The Royal Observatory Greenwich historical website, “Astronomical Regulator: Dent 1906”. Chronology and transcriptions of Airy’s introduction to the 1871 volume of Greenwich Observations and the introduction to the 1909 volume. Accessed November 20, 2026.
- [3] “The New Standard Sidereal Clock of the Royal Observatory, Greenwich”, Nature, 11, April 1, 1875, pp. 431–433. Text consulted in the transcription on the observatory history website. Accessed November 20, 2026.
- [4] Emily Akkermans, Kelley Wilder and Samantha Thompson, “Revealing observatory networks through object stories: Instrumental networks”, Science Museum Group Journal, 20, 2023, section on the time-signal instruments in the Computing Room. Accessed November 20, 2026.
- [5] Rory McEvoy, “The trouble with pendulums”, in Harrison Decoded, Oxford University Press, 2020. Section on nineteenth-century barometric compensation. Accessed November 20, 2026.
- [6] Royal Observatory Greenwich, Astronomer Royal’s reports for 1912 and 1923, in “Extracts from the Reports of the Astronomer Royal relating to the Time Service (1912–1964)”. Accessed November 20, 2026.
- [7] The Royal Observatory Greenwich historical website, “Astronomical Regulators: The Riefler and Cottingham Clocks”, sections on introduction and operation. Accessed November 20, 2026.