Shortt Free Pendulum Clock No. 3

This article was translated from Japanese using AI. Read the Japanese original

A clock accurate enough to raise questions about the definition of time#

Shortt Free Pendulum Clock No. 3 is the electromechanical clock that became the Royal Observatory Greenwich’s sidereal standard on 1 January 1925. William Hamilton Shortt designed it, and the Synchronome Company of London made it. The National Maritime Museum records it as ZAA0539. No. 3 identifies the first such installation the observatory adopted. 12

The design leaves the precise pendulum free of the work of driving hands and recording equipment by assigning those tasks to another clock. Detailed analysis of discrepancies from observed time revealed that some came from astronomical variations in the sidereal reference. No. 3 illustrates the connection between making a good clock and deciding what counts as uniform time. 3

Two instruments in one clock system#

Master pendulum and slave clock#

Wires connect a master pendulum in a reduced-pressure enclosure to a slave clock in a mahogany case. The master enclosure is a painted copper tube with thick glass at the bottom and a glass dome at the top for viewing the interior. The slave clock has two silvered dials. The nominal seven-inch dial is marked “Synchronome Electric” and the four-inch dial “Free Pendulum”. The finished wooden case and laboratory-like enclosure reflect the different jobs of the two instruments. 1

The master pendulum provides time stability. The slave clock counts swings, drives the display and dictates when the master is to receive an impulse. An electrical signal from the master in turn corrects the phase of the slave clock. The two instruments share different tasks in a control system with signals travelling in both directions. 34

At Greenwich, the master pendulum stood in a cellar beneath the Octagon Room and the slave clock in the ordinary clock room across a courtyard. The observatory’s 1925 annual report records the layout and the start of operation on 1 January. The cellar’s thick walls and stable temperature helped, though the floors and walls required work to counter damp. 2

Impulse every 30 seconds#

In a conventional pendulum clock, the escapement releases the train one tooth at a time and gives energy back to the pendulum. Friction and changes in impulse can disturb the period being measured. The Shortt keeps the master pendulum swinging freely for long intervals and gives it an impulse from a small gravity arm once every 30 seconds. 3

When the slave clock releases the gravity arm electrically, its end contacts a small wheel attached to the master pendulum. Energy passes to the pendulum as it crosses near the centre and continues its swing. When the arm leaves the wheel, a mechanism resets it. This action also generates a synchronising signal back to the slave clock. Impulse and extraction of a timing signal are confined to this short interval, leaving the pendulum free from the load of the train for the rest of the time. 13

The pendulum still operates under air resistance and relies on its suspension spring, mounting and intermittent drive. No. 3 has an Invar master pendulum rod, and the 1928 report gives the pressure in its enclosure as about one inch of mercury. This partial vacuum reduces the effect of air. 3

Advancing the slow clock only when needed#

The slave clock is set to run a little slow on its own. When the signal from the master arrives and sufficient lag has accumulated, an electromagnetic arm acts on a thin spring on the slave pendulum to advance its phase. If the phase is close enough, the arm misses. This is hit-and-miss synchronisation, which intersperses correction cycles with cycles requiring none. 4

Figures differ by source and date. In 1928 Jackson and Bowyer gave a slave rate of about five seconds slow per day and a phase advance of about 0.004 seconds per correction. Spencer Jones’s general account of 1949 gives about six seconds per day and about 1/240 of a second. The principle is the same, but the general figures leave open what settings No. 3 used at different points in its service. 34

Performance in operating records that include faults and corrections#

The stoppage of 1926 and changes to the mechanism#

No. 3 went into operation at the beginning of 1925 with nearly zero daily rate, then began losing time at an increasing rate. The 1928 report gives the initial change in daily rate as about 0.04 seconds per day per month, falling to about 0.012 seconds per day per month from autumn 1925. These figures describe how the daily rate changed over time. 3

In June 1926, the master pendulum stopped after the mechanism that reset its impulse arm failed to release. Sticking between two steel surfaces was identified as the cause. A jewel contact was added at the catch and the clock restarted in July. Precision in service depended on correcting such faults at the contact surfaces. 3

Temperature and long-term change in Invar#

After temperature control was added, a temperature effect remained. The 1928 analysis found a term of about 0.0030 seconds per day per degree Fahrenheit. It also related the long-term change in the daily rate to elongation of the Invar pendulum. Low thermal expansion and long-term dimensional stability are distinct properties. 3

The paper reported that a predictive equation accounting for temperature, variations in sidereal time and other factors agreed with observations to within 0.1 seconds from March to December 1927. 3

The clock as a sidereal standard#

Sidereal time uses stellar meridian transits to measure Earth’s rotation. Its day has a different length from the mean solar day used in civil life. A standard clock carries forward the time and daily rate determined from observations through periods in which observations are unavailable. 4

The analysis of No. 3 reached a precision at which the short-period components of nutation affecting the position of the vernal equinox had to be taken into account. Jackson and Bowyer included nutation in their equation for the discrepancies and accounted for the observations. A better clock reveals smaller variations in the astronomical reference against which it is compared. It therefore became important in practice to distinguish sidereal time based on the true equinox from mean sidereal time, which removes nutation. 34

No. 3’s performance alone leaves changes in the Earth’s rotation unresolved. The 1928 authors themselves discuss the difficulty of separating long-term changes in the pendulum material from those in the Earth’s rotation. Spencer Jones later explained that small irregular rate changes in free pendulum clocks limited predictions over periods without observations. 34

Changes of standard, movements of parts and the surviving installation#

The 1930 annual report says No. 3 was taken down for service in October 1929 and its original type-metal weight replaced with a heavier Invar one. The change tested whether deformation of the lead-rich weight caused the increasing loss. The rate still fell afterwards, but the increase in loss over a comparable period was reportedly about half that seen before. No. 11 served as the standard from 1 August 1929 through 31 March 1930, a period that included the work. No. 3 resumed the role on 1 April. 2

The museum dates No. 3’s use as the sidereal standard to 1925–1938, allowing for such interim substitutions, and says it was superseded by a system using the mean of several clocks. No. 3 could continue to run and control signal circuits after the end of its role as the sole standard. 1

The 1940 annual report says that a new impulse wheel and support fitting were fitted on 3 August the previous year and that the weight carrier was cut down to offset the added mass. Its contacts were cleaned on 1 February 1940 and it was resealed on 24 April. The same report says the chronograph and sidereal circuit were driven by No. 3 until 31 July, when No. 11 took over. The reporting period places that date in 1939. 2

The sources disagree about the wartime location. The 1946 annual report lists Nos. 3, 11 and 16 as clocks used in Edinburgh. The observatory history says the reference to No. 3 may be an error, citing other years’ records that identify Nos. 11 and 16 as the clocks moved. No. 3’s transfer to Edinburgh remains uncertain. 25

In the October 1948 arrangement cited by the same history, the master remained installed but out of operation at Abinger, while the slave ran at Greenwich. After the war the slave clock was also paired with the master pendulum of No. 66. 5

The current collection record lists the master assembly, slave clock, pressure gauge, suspension, impulse arm, weight and glass cover among the separate components. It gives dimensions of 1,020 × 25 mm without identifying what was measured. The dimensions of the complete installation and continuity of its original parts are therefore separate questions. When checked on 13 November 2026, the public record for the assembly listed it as off display. Display locations can differ at component level, so this record cannot establish whether the full installation is viewable on site. 16

Timeline#

Date or periodEvent involving No. 3
Around 1924Date of manufacture by Synchronome given by the museum. 1
21 November 1924Delivery date in the observatory history. The master pendulum and slave clock are installed in separate rooms. 5
1 January 1925Begins operating as the sidereal standard. 123
June–July 1926Sticks and stops at the impulse return mechanism, then restarts with a jewel contact. 3
Late 1926–1928Temperature control and error analysis progress. The 1928 paper reports performance and limitations. 3
October 1929–April 1930Type-metal weight replaced with Invar during servicing. No. 11 substitutes until No. 3 resumes as the standard on 1 April. 2
1938Transition from a sole standard clock to a system using several clocks. 1
July–August 1939Control of the sidereal circuit passes to No. 11, and the impulse wheel and support are replaced. 2
February and April 1940Contact cleaning and resealing. 2
1943 reportRecords acquisition of a new enclosure for No. 3 adapted for photoelectric reading. Its permanent installation is unconfirmed. 2
1946 reportLists No. 3 among the clocks brought back from Edinburgh, conflicting with other sources. 25
October 1948Later research shows the master standing idle at Abinger and the slave operating at Greenwich. 5
Checked November 2026Assembly and component records are in the National Maritime Museum’s public catalogue under ZAA0539. 1

Significance in the history of timekeeping#

The records of No. 3 allow its measured performance, mechanical faults and repairs, and the reassessment of its time reference to be followed together.

References#

  1. Royal Museums Greenwich, “Shortt Free Pendulum System, No. 3”, ZAA0539, dated circa 1924. Object record. Accessed 13 November 2026.

2. Astronomer Royal, annual reports of 1925, 1926, 1930, 1940, 1943 and 1946, “Time Service” and related sections. Transcribed extracts by The Royal Observatory Greenwich. The transcription notes the possibility of errors. Accessed 13 November 2026.

3. J. Jackson and W. Bowyer, “The Accuracy of Shortt Free Pendulum Clocks”, Nature 121, 868–870, 2 June 1928. PDF of the original, printed pp. 868–870. Accessed 13 November 2026.

4. Harold Spencer Jones, “The Determination of Precise Time”, sixteenth Arthur Lecture, 14 April 1949. Lecture transcription. Its retrospective account differs on the year of installation, so the installation date of No. 3 follows the contemporary sources. Accessed 13 November 2026.

5. The Royal Observatory Greenwich, “Astronomical Regulators: Shortt ‘free-pendulum’ clocks Nos: 3, 11, 16, 40, 49, 61, 66 & 67”. Observatory history and source excerpts. Undated. Accessed 13 November 2026.

6. Royal Museums Greenwich, “Bell jar”, ZAA0539.11. Component record. Accessed 13 November 2026.