The S balance, John Arnold’s temperature compensation and surviving examples

This article was translated from Japanese using AI. Read the Japanese original

The S balance is a temperature-compensation device used by John Arnold in precision timekeepers in the late eighteenth century. Bimetallic elements bent into an S change shape with temperature, shifting the weights to compensate for the gain or loss caused by changes in the balance spring. The design is called an S balance in English, or a double S balance when the elements are arranged symmetrically.1 2

The name refers specifically to an Arnold compensation design with S-shaped bimetallic elements. Other S-shaped watch parts and later circular split balances are distinct forms.

Why heat makes a watch lose time#

The balance oscillates in rotation, and the balance spring supplies the restoring torque. As temperature rises, the elasticity of a steel balance spring changes. The dimensions of the balance also change, so the period can vary even when the watch remains in the same position. In his 1920 lecture, Charles-Édouard Guillaume identified the main cause of temperature error in a steel spring and brass balance as a change in the spring material’s Young’s modulus, a measure of resistance to deformation.3

Temperature compensation can act on the spring or the balance. Varying the spring’s active length changes its restoring torque. Varying the balance’s mass distribution changes the period without adjusting the spring directly. The S balance takes the latter approach.

The relationship can be expressed with a basic model of rotational motion. Neglecting friction and drive and assuming that restoring torque is proportional to angle gives the following equations.

\[ I\ddot{\theta}+\kappa\theta=0,\qquad P=2\pi\sqrt{I/\kappa} \]

Here I is the balance’s moment of inertia (kg m²), θ the angle of rotation (rad), κ the restoring torque per unit angle (N m/rad), and P the period of one complete oscillation (s). This is a linear oscillator model explaining the direction of compensation, rather than a calculation of accuracy from the dimensions of an actual watch. It uses the standard torsional oscillation equation with the period denoted P.8

If heat reduces κ, reducing I can limit the increase in period. Moving a weight towards the axis reduces the moment of inertia, which is why weights that move with temperature are useful. The device compensates for changes in the oscillator, including the spring, rather than merely preventing the balance from expanding.

How the S-shaped elements work#

A bimetallic element joins metals that expand differently with temperature. Sotheby’s catalogue for No. 23/78, based on examination of the watch, describes shaped bimetallic bars intended to compensate for changes in spring elasticity and expansion of the balance rim.2

The French-language technical history at Horlogerie Suisse traces the development from the early compensation arrangement to a symmetrical pair of S-shaped bimetallic elements from 1779 onward. Deformation of the two elements with temperature changes the distance from the axis to the weights. The way the elements are fixed and the positions of the weights have to be checked on each watch. A schematic alone cannot establish the construction of every example.4

Adjustment has two aims: obtaining the right period at ordinary temperature and reducing how much it changes at high and low temperatures. A later adjustment manual explains how temperature trials and changes to weight positions are used to set the amount of compensation. This explains compensation balances in general. Its instructions for moving screws concern a later practice than Arnold’s eighteenth-century S balance.5

Dating the watch and its balance#

No. 28, a watch of 1776–1777 with an S balance added later#

The Science Museum Group’s record for Arnold No. 28 describes a pocket watch with a silver-gilt case, small seconds and a pivoted detent escapement. The case hallmarks date to 1776–1777. The museum explicitly says the S balance was added later and dates the use of this type to 1779–1782.1

The case date therefore cannot establish that the S balance was complete as early as 1776. Surviving watches can preserve historical improvements. The date of the watch, the case hallmarks and the date of its present mechanism provide different clues to the development of the technique.

No. 23/78, a documented combination from 1781#

No. 23/78, catalogued by Sotheby’s in 2016, is a silver-cased pocket chronometer with 1781 hallmarks. It combines a pivoted detent escapement, S balance, blued steel cylindrical balance spring and chain fusee. The fusee evened out changes in the force of the mainspring, while the S balance provided temperature compensation.2

The catalogue describes it as an unrestored example retaining its original case, dial, escapement and double S balance.

What the dates and patents establish#

Sources give a range for the introduction. The museum gives 1779–1782 for the period of use, and Sotheby’s dates the double S design to 1780. The two accounts can coexist, but the surviving manufacturing records do not fully distinguish prototyping, adoption and later fitting. A 2023 Sotheby’s catalogue groups T and S designs as types used from 1778 onward. That grouping gives no separate start date for the S balance. The S design’s introduction is generally placed around 1779–1780, while some sources include it in a group of improvements used from 1778.1 2

Arnold’s 1775 patent on temperature compensation and springs and his 1782 patent No. 1328 mark important dates. A specialist object catalogue says the later patent describes compensation balances including the T and S designs. The full original specification and drawings were unavailable for this article, so the evidence does not establish that the complete S arrangement was patented in 1775 or first made in 1782.6 7

Museum sources and object descriptions document the surviving parts and how they work. Determining the scope of the patent claims requires the patent itself.

Later split balances and the limits of compensation#

A typical later compensation balance uses an arcuate rim combining steel and brass, with cuts that let the free ends bend as the temperature changes. The form differs from the S-shaped elements, but both designs vary the mass distribution with temperature. Guillaume’s lecture explains the “secondary error” of bimetallic compensation, a residual error at intermediate temperatures after adjustment at high and low temperatures.3

Movement of the weights can leave residual errors. The temperature response of the spring and the deformation of the bimetal need not follow the same curve over a wide range. Specific errors measured for later steel-and-brass split balances cannot serve as figures for S balance performance without corresponding tests.

In the twentieth century, another approach controlled the thermoelastic properties of the spring material and paired it with a monometallic balance. Surviving S balances document an earlier use of material deformation to compensate automatically for temperature error within the watch.3

Timeline#

DateRelation to the S balance
1775Arnold’s patent for temperature compensation and springs, separate from the date of completion of the S design
1776–1777Case date of No. 28. Its present S balance was added later.
c. 1779–1780Period given in the sources for development and introduction of the S and double S designs
1781Case date of No. 23/78 with its S balance
1782Patent No. 1328. The original drawings and full text were unavailable for this article.
Nineteenth century onwardCompensation designs including the split balance develop as separate forms.
1920Guillaume lectures on the limits of bimetallic compensation and the use of spring materials to address them.
TodaySurviving watches such as No. 28 and their collection records allow comparison of designs and alteration histories.

References#

  1. Science Museum Group, Pivoted-detent escapement watch by John Arnold, L2015-3332 / Clockmakers’ Museum no. 419. No. 28, the 1776–1777 hallmarks and the later addition of the S balance.

2. Sotheby’s, John Arnold, London, No.23/78, July 7, 2016, lot 38. “Description”, “Condition” and “Catalogue Note”.

3. Charles-Édouard Guillaume, Invar and elinvar, Nobel Lecture, December 11, 1920, pp. 469–471. Consulted in the PDF reproduction of the lectures, PDF pp. 26–28, for the thermal properties of compensation balances in general.

4. Horlogerie Suisse, John Arnold, in French, figs. 2–3 and accompanying text. A later technical history giving the transition to S-shaped bimetallic parts from 1779 onward.

5. Walter J. Kleinlein, Rules and Practice for Adjusting Watches, 1920, part I. Later practice in adjusting compensation balances.

6. Arnold & Son, Heritage, timeline entries for 1775 and 1782.

7. Sotheby’s, Important Watches Part I, GE2301, 2023, pp. 112–113. Discussion of patent No. 1328 and the T, S and OZ types. Consulted for the catalogue account rather than as a substitute for the patent drawings.

8. OpenStax, University Physics Volume 1, 15.4 Pendulums, “Torsional Pendulum”, eq. 15.22. Linear model of a rotational oscillator.