The Invar pendulum#
This article was translated from Japanese using AI. Read the Japanese original
An Invar pendulum for a precision clock uses a rod of an iron–nickel alloy that changes little in length with temperature. The French term is pendule à tige d’invar, and German terms include Nickelstahl-Kompensationspendel. Invar is a low-expansion alloy containing roughly 36% nickel. It allows the large compensating mechanism needed with an ordinary steel rod to be replaced with small compensating parts. Expansion varies with composition and heat treatment, so the rod still needs adjustment in use. 1 2 3
The technology improves how the clock’s oscillator responds to temperature. Separate mechanisms provide power and release the train in steps. Riefler’s precision clocks combine an Invar rod, tubes compensating for residual expansion, a suspension spring, an escapement and measures to reduce the effects of air pressure. The Invar pendulum chiefly limits temperature-related changes in the dimensions and mass distribution of the oscillating system. 3 5
From steel rods to low-expansion alloys#
A pendulum with its bob below a metal rod becomes longer as it warms and generally swings more slowly. Precision clocks countered the rod’s downward expansion with another expansion that lifted the bob. A mercury compensation pendulum uses mercury’s upward expansion. A gridiron connects rods of different metals in an alternating upward and downward path. Invar reduced the problem by changing the material of the rod itself. 5 12
Guillaume’s measurements and collaboration with the steelworks#
Charles-Édouard Guillaume’s 1897 report for the International Bureau of Weights and Measures traces the research to March 1895. His colleague René Benoît observed unusually large expansion in a steel rod containing nickel and chromium. In May 1896 Guillaume identified a chromium-free nickel steel that expanded less than platinum. On Benoît’s advice he sought the help of L. Dumas of the steel company Commentry-Fourchambault. Its Imphy works prepared 17 alloys with different nickel contents. 1
The expansion does not simply average the behaviour of iron and nickel in proportion to their amounts. The lowest expansion in the 1897 table occurs near 35.7% nickel, and alloys of similar composition have different coefficients. This unusual dependence on composition made the material useful in precision instruments. A later U.S. Bureau of Standards report examined the unusual behaviour of these alloys, including their magnetic properties and processing history as well as expansion. 1 2
The historical term nickel steel can refer to steels containing nickel in general. Low-expansion rods for clocks and nickel steels chosen for uses such as compensation balances can have different compositions and properties. Invar has low expansion, while Elinvar limits changes in elastic modulus with temperature. A pendulum depends mainly on its effective length. Oscillation of a sprung balance depends mainly on the balance’s moment of inertia and the spring’s stiffness. 2 12
Early pendulums and trials#
An abstract of Guillaume’s lecture published in La Fédération horlogère suisse in 1901 describes a pendulum that he made in March 1897. The bob sat on a nut at the bottom of the rod. Upward expansion of the bob itself compensated for the small expansion of the nickel steel rod. Riefler’s later patent describes a different arrangement with a separate compensation tube. 13
According to the same abstract, Caspari began testing a pendulum of the same design made by Méaume at the French Navy’s hydrographic service in May 1898. It showed an average rate of 0.2–0.3 seconds per day over a period of about six weeks, but there were also sudden changes in rate. Guillaume suspected that parts were sticking, though the cause was unconfirmed. A low-expansion material alone could not deliver high accuracy without adjustment. Méaume also found low cutting speeds and plenty of oil useful for turning and threading. After discovery of the material, machining, assembly and testing presented their own problems. 13
How temperature changes affect rate#
Consider an ideal simple pendulum at small amplitude. Let \( P \) be the period of one complete oscillation, \( L \) the length and \( g \) the acceleration of gravity.
For a temperature change \( \Delta\theta \) and a coefficient of linear expansion \( \alpha \) taken as constant over a narrow range, \( \delta L/L\simeq\alpha\Delta\theta \). As the rod lengthens, each cycle lasts longer, and a clock counting the oscillations loses time. 9 10
A rod with \( \alpha=1.0\times10^{-6}\,\mathrm{K}^{-1} \) would, for example, produce a daily loss of about 0.0432 seconds for each 1 °C increase due to rod expansion alone. This illustrative figure comes from \( 86400\times\alpha/2 \). Multiplying the rod’s coefficient by twelve gives about twelve times the loss. Invar reduces this sensitivity. The calculation excludes the bob, compensator, air and support. 5 9 10
The height of the centre of mass is only part of the calculation#
A real pendulum has a rod with mass, a bob with physical extent, a nut and compensating parts. For a rigid pendulum at small amplitude, take \( I \) as the moment of inertia about the pivot, \( M \) as the total mass and \( d \) as the distance from pivot to centre of mass.
\( L_{\mathrm{eff}} \) is the effective length, the length of a simple pendulum with the same period. The units are seconds for period, metres for length, kilograms for mass, kg m² for moment of inertia and m/s² for gravitational acceleration. 9
Even with the bob’s centre at the same height, expansion of the bob itself and changes in mass distribution along the rod affect the moment of inertia. Precise temperature compensation therefore concerns the effective length of the whole oscillator, beyond the position of the rod’s tip or the centre of mass. The 1911 Encyclopædia Britannica describes an Invar pendulum calculated using the moments of inertia of the individual parts and the position of the bob’s support. The rigid-body model omits effects such as elasticity of the suspension spring and the action of the air. 5 9
Riefler’s compensation tubes and adjustment#
Lifting the bob by the amount the rod expands#
German patent DE100870C describes a low-expansion nickel steel rod, a bob, an adjusting nut and two compensation tubes. Compensating parts between a nut at the lower end of the rod and the bob support expand upwards as they warm. The downward expansion of the rod is small enough that the compensator can be short. 3
The patent provides a way to adjust the amount of compensation. Small variations in nickel content affect expansion, so identical compensators will not suit every rod. Two tubes of materials with very different coefficients are stacked in lengths that can be varied. Keeping their total length constant at the reference temperature lets the maker adjust how much the stack expands without changing the bob’s basic position. 3
If the lengths are \( l_1,l_2 \) and the coefficients are \( \alpha_1,\alpha_2 \), the expansion for the same temperature change is approximately \( (\alpha_1l_1+\alpha_2l_2)\Delta\theta \). Even if \( l_1+l_2 \) stays the same, a different proportion changes the expansion. The expression illustrates the patent’s adjustment principle using linear expansion. It omits the masses of the bob and rod, which also matter when determining final dimensions. 3 10
The claim covers two or more compensation tubes. The description lists material options including nickel steel, glass, steel, brass and zinc, leaving the materials of individual clocks to be verified. Fintan Kindler’s 1905 technical book describes one version of the Riefler seconds pendulum with a brass tube and a steel tube, each about 10 cm long. 3 4
Measuring expansion and stabilising the alloy#
Makers measure the particular rod and condition it thermally before selecting a compensator. An alloy designation alone gives insufficient information about its expansion. Low thermal expansion and dimensional stability over years are distinct properties. After machining or heating and cooling, a rod may fail to return immediately to its previous length at the same temperature. 1 2
The U.S. Bureau of Standards’ 1923 report distinguishes transient length changes after a change in temperature from changes that continue for long periods at constant temperature. Figure 38 compares a bar left to cool after forging with one cooled from 150 to 40 °C over 50 days. The latter still changed dimension, but its subsequent elongation was smaller. The vertical axis shows elongation per metre and the horizontal axis days. The chart gives material behaviour rather than a direct clock rate. 2
The report distinguishes Guillaume’s stabilising process, étuvage, from ordinary annealing. One example lowers the temperature from 100 to 20–25 °C over two to three months. A study of Riefler’s manufacturing history describes treatment in a dedicated furnace for about twenty days. These accounts refer to different materials or processes and do not establish a single procedure. 2 6
Guillaume’s 1899 follow-up also cautions about measuring the coefficient for a clock. A sudden temperature change gives different behaviour from the slow variations of a clock room. He recommended the expression that corresponds to the latter. A brief heating test of one rod therefore has limits as a basis for the long-term compensation of a clock. 14
Errors that remain with low expansion#
Air density and temperature differences with height#
A pendulum swinging in air experiences buoyancy and moves the surrounding air, both of which affect the period. Heating usually expands metal but decreases the density of air at constant pressure. Compensating for all of the rod’s expansion alone may leave a temperature coefficient in the complete clock. Compensation must also account for the bob’s material and dimensions, air density and conditions inside the enclosure. 5
If the top of the rod and the compensator below are at different temperatures, compensation based on a common temperature change breaks down. This can happen when heating produces layers of different temperatures in the room. Studies describe Riefler as developing a pendulum for temperature stratification from 1908 onwards. It placed the compensation elements at the top. The position of parts and how heat reaches them remained design questions even with a low-expansion alloy. 6
Compensation and the accuracy of the whole clock#
Even with an Invar rod the period depends on escapement impulse, amplitude, the suspension spring, the wall or other support and air pressure. Riefler’s precision clocks depended on more than one material. Kindler reports a temperature sensitivity of ±0.02 seconds per day per °C for the nickel steel pendulum he describes. 4 5
A Lawrence Berkeley National Laboratory engineering guide consulted in October 2026 also distinguishes low thermal expansion from long-term dimensional stability and points out the effects of heat treatment and machining. In restoration, replacing a historical rod with a new one of the same nominal composition is insufficient to assume the compensation will be reproduced. 11
Evidence of use and place in horology#
The German scientific-instrument exhibition catalogue for the 1904 St. Louis World’s Fair gives 1898 as the introduction of Riefler’s nickel steel compensation pendulum. Material research, early prototypes, the patented structure and introduction as a product were separate stages. The catalogue says the expansion of each rod was measured initially at Germany’s Physikalisch-Technische Reichsanstalt and later at the BIPM. The results were used to calculate the compensators. 15
As an example in service, the catalogue quotes observations published in an astronomy journal in 1902 for clock No. 56 at the observatory in Cleveland. Over several months it gives a mean daily variation in rate of 0.015 seconds and a maximum of 0.022 seconds. The catalogue reports rate variations for the whole clock, including the escapement and enclosure. The figures reach us through the catalogue’s quotation of the observations. 15
Museums Victoria in Australia holds Riefler regulator No. 289 from 1910, used by the meteorological authorities in Melbourne. Its catalogue records the dial inscription of the number corresponding to DE100870 and a separate number on the movement. The clock and patent numbers identify different things. The record also describes the free pendulum and transmission through the suspension spring, illustrating separate roles for the compensation rod and escapement. 7
A report published by the National Astronomical Observatory of Japan in 2007 documents a bob found in the Repsold transit instrument room. It shows the back inscription “RIEFLER MÜNCHEN D.R.P 100870 2673” in a photograph and records a diameter of 22 cm and mass of 6,090 g. It confirms the presence of a part associated with Riefler’s nickel steel compensation pendulum. The bob alone cannot establish the composition of the rod used there or how the complete clock performed. 8
In his 1920 lecture Guillaume explained that using an Invar rod and metal bob simplified complicated compensation systems including mercury. He also expected operators to check their clocks regularly and track slow changes in rate. The Invar pendulum made it easier to measure, adjust and maintain a stable oscillator, while time and the environment could still affect it. 12
Timeline#
| Date | Research, design and use |
|---|---|
| By the nineteenth century | Mercury and combinations of dissimilar rods are developed for pendulum temperature compensation. 5 12 |
| March 1895 | Benoît notices abnormal expansion in a nickel–chromium steel bar. Guillaume’s 1897 report identifies this as the start of the research. 1 |
| May 1896 | Guillaume measures low expansion in a nickel steel and begins systematic studies with Imphy. 1 |
| March 1897 | Guillaume makes a pendulum using expansion of the bob itself, according to the 1901 lecture abstract. 13 |
| 1897 | Guillaume reports expansion by alloy composition, time- and temperature-dependent changes and treatments to the International Committee for Weights and Measures. 1 |
| Late nineteenth to early twentieth century | DE100870C describes a nickel steel rod with two or more compensation tubes. The patent number is later marked on products. 3 7 |
| 1898 | Year given for the introduction of Riefler’s nickel steel compensation pendulum in the manufacturer’s 1904 exhibition catalogue. 15 |
| May 1898 | Testing begins at the French Navy’s hydrographic service on Méaume’s pendulum of the same type as Guillaume’s. The lecture abstract describes the trials. 13 |
| 1899 | Guillaume’s follow-up recommends coefficients suited to slow temperature change when compensating a clock. 14 |
| 1902 and 1904 | Observations of No. 56 are reported and quoted in the 1904 exhibition catalogue. The results concern the complete instrument. 15 |
| 1905 | Kindler describes a Riefler pendulum with brass and steel tubes. 4 |
| From 1908 | Riefler develops a compensation pendulum to deal with different temperatures at the top and bottom. 6 |
| 1910 | No. 289, now at Museums Victoria, is made. 7 |
| 1911 | The Encyclopædia Britannica describes moments of inertia, artificial ageing and effects of air on Invar pendulums. 5 |
| 11 December 1920 | Guillaume discusses pendulums in his Nobel lecture “Invar and Elinvar”. 12 |
| 22 June 1923 | The U.S. Bureau of Standards issues the second edition of Invar and Related Nickel Steels, documenting low expansion and dimensional changes with age. 2 |
| November 2007 | The National Astronomical Observatory of Japan reports the Riefler bob and inscription found in the Repsold transit instrument room. 8 |
| Verified in October 2026 | Public collection records and engineering material document the provenance of surviving objects and the handling of low-expansion alloys. 7 11 |
References#
- Ch.-É. Guillaume, “Étude sur les aciers au nickel”, Procès-verbaux du Comité international des poids et mesures, 1897, pp. 97–108. Measurements by composition and material history. Original BIPM records (PDF).
2. U.S. Bureau of Standards, Circular No. 58: Invar and Related Nickel Steels, 2nd ed., 22 June 1923, particularly pp. 53–56 and 79–80, fig. 38. U.S. government PDF.
3. German patent DE100870C for a pendulum with a nickel steel rod and compensating tubes, description and claims. Original German text consulted. The electronic record lacks dates, and the text does not establish filing or publication dates. German text on Google Patents.
4. Fintan Kindler, Die Uhren, 1905, pp. 129–131, fig. 44. Consulted for construction, dimensions and reported performance, as material composition figures are inconsistent. Project Gutenberg text.
5. Encyclopædia Britannica, 11th ed., vol. 6, 1911, “Clock”, pp. 539–541, especially “Invar” and “Barometrical error”. Project Gutenberg text.
6. Bernhard Huber, “The Engineer of Precision Time: Pendulum Clocks by Sigmund Riefler”, Jahrbuch 2019, Deutsche Gesellschaft für Chronometrie, pp. 268–270. Heat treatment and compensation for temperature differences with height. Society PDF.
7. Museums Victoria, “Item ST 24606: Regulator Clock – Riefler, Munich, 1910”. Collection, users and inscriptions of No. 289. Collection record.
8. National Astronomical Observatory of Japan, “NAOJ’s historical observing team investigates the mysteries of the Repsold transit instrument room, part 2”, NAOJ News, no. 172, 1 November 2007, pp. 8–10, especially the bob on p. 9. Original issue (PDF).
9. OpenStax, University Physics, vol. 1, §15.4 “Pendulums”. General equations for simple and rigid pendulums at small amplitudes. Textbook.
10. OpenStax, University Physics, vol. 2, §1.3 “Thermal Expansion”. First-order approximation and units for linear expansion. Textbook.
11. Lawrence Berkeley National Laboratory, MEDSI Engineering Design Guide, “Materials / INVAR”. Low expansion, long-term dimensional stability, and the effects of machining and heat treatment. Engineering guide.
12. Charles-Édouard Guillaume, “Invar and Elinvar”, Nobel Lecture, 11 December 1920, particularly pp. 468–471. Reprint of the English edition. Lecture reprint (PDF), Columbia University.
13. “L’acier-nickel”, La Fédération horlogère suisse, year 16, no. 89, 10 November 1901, pp. 514–515. Contemporary abstract of Guillaume’s 1900 lecture, reprinted from La France Horlogère. Original issue (PDF), former RERO site / current catalogue.
14. Ch.-É. Guillaume, “Nouvelles recherches sur les aciers au nickel”, Procès-verbaux du Comité international des poids et mesures, vol. 21, 1899, annex III, particularly pp. 168–170 and 178–179. Original BIPM records (PDF).
15. Scientific Instruments: German Educational Exhibition, World’s Fair, St. Louis, 1904, Riefler exhibit, pp. 114–119, particularly pp. 117–119. Manufacturer’s account and observations quoted in the catalogue. Extract (PDF), University of Munich.
Sources and collection information accessed on 27 October 2026.