The Palmer micrometer, or Système Palmer, converts the rotation of a screw into a small linear movement. It measures the thickness or outside diameter of an object held between two faces. The design descends from a portable instrument patented in France in 1848 by Jean-Laurent Palmer. Its combination of scales on a fixed sleeve and rotating thimble survives in the modern outside micrometer. 1 2
Its connection to horology is through measuring the dimensions needed to make a watch. A late nineteenth-century manual for watchmakers describes a Brown & Sharpe micrometer for measuring mainsprings, pinions and other small parts. It helped make numerical comparisons possible when manufacturing components that previously might have been judged approximately the same size. 5
What is a Palmer micrometer?#
Palmer’s original, American tools using its scale arrangement and modern outside screw micrometers represent different stages of the design. In French, palmer still denotes a tool for measuring thickness. A micrometre is also a unit of length equal to one thousandth of a millimetre (µm). The name of the tool by itself guarantees no 1 µm accuracy. 1 6 8
The use of a screw for measurement predates Palmer. Mitutoyo’s technical history includes Gascoigne’s astronomical measurements in the seventeenth century and bench instruments by Watt and Maudslay. Palmer’s contribution was to combine a workshop calliper that could be carried in a pocket with a scale that was easy to read. 2 4
The 1848 patent and a contemporary account#
Date of the patent and limits of the evidence#
The Science Museum Group’s record for Palmer gives a patent dated 7 September 1848, number 7518, titled calibre à vis et à vernier circulaire. The report on the retrospective exhibition at the 1900 Paris Exposition gives the same date and title, citing plate 46 in the patent publications for 1847–1849. 2 3
That is the date attributed to the patent in the sources. The individual dates of application, registration and publication have not been checked. Later retrospective drawings and collection objects cannot by themselves establish the original patent’s claims. A more detailed contemporary account describes the construction and use. 1 3
There is also a discrepancy in numbering. The Science Museum Group catalogue for drawing 1960-34 says the drawing comes from French patent 3762, while the museum’s record for Palmer gives 7518. Until the original text can be checked, the discrepancy remains open and the number alone is insufficient to identify the invention conclusively. 2 3
Parts and operation in the report of 1850#
Alcan’s report in the bulletin of the French Society for the Encouragement of National Industry was approved on 19 December 1849 and printed in the 1850 volume. After describing Palmer’s work on tubes and related projects, it explains a gauge with a circular scale for measuring sheet thickness. The instrument resembles a clamp. It has a fixed contact face at one end and a stationary internally threaded sleeve at the other. The screw carries a rotating thimble, with the graduations engraved on its thin bevelled edge. 1
The screw advances 1 mm per revolution. The fixed sleeve has longitudinal marks at 1 mm intervals and the thimble has 20 equal divisions. Bringing the faces together aligns the zeros of the fixed and circular scales. When a part is between the faces, the reading is the whole millimetres showing on the sleeve plus the twentieths of a millimetre given by the circular scale. The report cites copper sheet, zinc sheet and tinplate as applications and notes that the tool fits in a pocket. 1
The contemporary report praised the tool as more convenient and precise than earlier gauges. It gives no modern calibration or measurement uncertainty tests. Its stated 0.05 mm scale interval does not establish a maximum error of 0.05 mm. 1 6
Graduations on the original, the replica and in later accounts#
The Science Museum Group’s 1928-1120 is described as a Brown & Sharpe replica made in or after 1867 of Palmer’s 1848 instrument. The entry gives a range of 0–20 mm, a 1 mm screw pitch, 20 divisions on the circular scale and a 0.05 mm scale interval, consistent with the 1850 report. Mitutoyo’s history describes a Palmer type with ten divisions on the circumference and readings to 0.1 mm. 1 4 7
The two accounts give different specifications. The available sources cannot establish 20 divisions for every Palmer type or ten for the original on the strength of a later summary. 1 4 7
Karl Karmarsch’s measurements, published in 1855, offer another piece of evidence. A steel instrument signed Palmer and bought in Paris had a 1 mm pitch, a 15 mm longitudinal scale and numbers 0 to 9 on the circular scale, with intermediate lines. Its ten numbers were therefore spread across 20 reading intervals, giving a direct reading to 0.05 mm. That instrument alone cannot establish where the later account of ten divisions came from. 9
Turning screw rotation into a dimension#
Pitch and the circular scale#
Let p be the distance the screw advances in one revolution and N the number of equal divisions around the circular scale. The linear movement r for one graduation is as follows. 1 5
This geometric relationship assumes constant pitch, proper engagement between the screw and sleeve, and a thimble that turns with the screw. p and r use the same unit of length, and N is a dimensionless number of divisions. Pitch error, play and deformation of the measuring faces are outside the formula. 1 6
| Example | Screw advance | Circular divisions | Movement per division |
|---|---|---|---|
| Palmer type in the 1850 report | 1 mm/turn | 20 | 0.05 mm |
| American type in the 1894 manual | 1/40 inch/turn | 25 | 0.001 inch |
| Worked metric example | 0.5 mm/turn | 50 | 0.01 mm |
The third row illustrates the principle with a metric example and gives no specifications for the 1848 instrument. A smaller pitch permits a finer reading but requires more turns for the same opening or closing distance. The choice of quick travel or fine adjustment according to the application remains part of modern micrometer head design. 6
Adding the fixed and rotating scale readings#
With the 1850 design, if the sleeve shows 3 mm and the thimble sits seven 0.05 mm intervals past zero, the reading is 3 + 7/20 = 3.35 mm. The seven counts intervals. It need not be the numeral seven printed on a scale numbered 0 to 9. On the inch model in the 1894 manual, one interval on the sleeve is 0.025 inch and one division on the thimble is 0.001 inch. Figure 135 shows three sleeve intervals and zero on the thimble, giving 0.075 inch. 1 5
The fixed part counts whole revolutions and the rotating part fractions of a turn. Arranging the numbers and lines across two scales made them easier to read than complex lines on a single sleeve. This helped the design gain adoption in the United States. 2
Redesign and manufacture in the United States#
Resolving differences among sheet gauges#
Joseph Wickham Roe’s history of tools describes a problem in the United States in 1867. Brass-sheet manufacturers, buyers and third parties used gauges that disagreed. S. R. Wilmot of Bridgeport Brass devised a small screw gauge with spiral and parallel lines on the cylinder. Those lines made it hard to read as a commercial product. 2
The same year Joseph R. Brown and Lucian Sharpe saw Palmer’s instrument at the Paris Exposition and took one back to the United States. In Sharpe’s recollections quoted by Roe, they combined Palmer’s scale arrangement with the size Bridgeport wanted, adding a clamp to lock the screw and an adjustment screw to compensate for wear at the measuring end. The design adapted Palmer’s tool to a specific need in the sheet-metal trade. 2
The stages of 1868, 1869 and 1877#
Roe says the “Pocket Sheet Metal Gauge” was introduced in 1868 and listed in the 1869 catalogue. A one-inch micrometer appeared in the 1877 catalogue. Mitutoyo says the gauge was made in 1868 and commercialised the following year. The wording differs on market introduction, and the small sheet gauge of 1868–1869 and the one-inch model of 1877 were separate products. 2 4
These dates are from accounts of Brown & Sharpe’s products. The sources give no worldwide dates for the start of mass production or widespread adoption. Roe’s history incorporates recollections from later in the participants’ lives and differs as evidence from a contemporary technical report. 1 2
What did watchmakers measure?#
Section 310 of the 1894 expanded American edition of The Watchmakers’ Hand Book is headed “Micrometer Caliper”. The Brown & Sharpe tool in fig. 135 is described as measuring from 0.001 to 0.5 inch and reading in 0.001 inch increments. The manual distinguishes a metric model reading to 0.01 mm and inch models with finer graduations. 5
The examples include mainsprings and pinions. A square edge on the measuring faces, without a bevel, made it easier to get under a shoulder or against a small projection. The manual also describes the spindle passing through the internally threaded sleeve and a hollow thimble that covered and protected the screw. The shape and reach of the faces mattered to watchmakers alongside the fineness of the screw. 5
One reading across a pinion cannot establish the tooth profile, uniformity of all its teeth or roundness of the arbor. When measuring a thin, elastic part such as a mainspring, the force must also be low enough to avoid deforming it. 5 6
Alcan’s 1850 report also says Palmer made an instrument to check the diameter and depth of watch glasses, used in Berger Walter’s factory in Lorraine. This was a different instrument described in the same report. It supplies no evidence for first use of the Palmer micrometer in a watch factory. 1
What determines accuracy beyond the scale#
Figure 1. Components of a modern outside micrometer. Palmer’s original had a different configuration. Drawing by Anasofiapaixao, based on Three-quarter-ten. Wikimedia Commons, original diagram. CC BY-SA 4.0. Changes from the original were vectorisation, conversion to metric and numbering. The resulting image is unmodified here.
Numbers 1–8 are the anvil, spindle, ratchet stop, sleeve, frame, thimble scale, lock nut and thimble.
Nineteenth-century work on measuring force and error#
Karmarsch compared the Palmer type and another sheet gauge and considered how they might be used to measure paper. He saw an advantage in the flat faces’ broad contact and the ability to read whole and fractional turns together. He also discussed the effects of play, screw error at different positions, tightening and compression of the paper. He mentions estimating to 0.01 mm by eye, distinct from directly reading the 20 divisions. 9
The report shows that European engineers were assessing the instrument in practical use before its American introduction in 1867. American adoption subsequently helped spread it more widely. 2 9
Measuring faces, materials and contact force#
A modern micrometer has a fixed anvil, a moving spindle, a frame supporting both, a thimble, sleeve scale, lock and constant-force device. Mitutoyo’s technical material shows carbide-tipped faces, insulated grips and ratchet or friction constant-force devices, all features of later instruments. 6
Greater measuring force increases elastic deflection of the frame and contact deformation of the workpiece. When a sphere or thin cylinder touches a plane, the small area of contact makes the reading especially sensitive to the shape and elastic properties. Constant-force devices help make the force repeatable. The appropriate force still depends on the material and part. Some designs use a non-rotating spindle to avoid the twisting action of a rotating measuring face. 6
The same guide describes using an optical flat to check face flatness and optical parallels to check that the two faces are parallel. Interference fringes reveal irregularities and tilt. A precisely made screw cannot prevent the reading from depending on where the workpiece sits if the faces are tilted. 6
Temperature, orientation and calibration#
Holding the frame for a long time transfers heat and shifts the reference position. The instrument, workpiece and standard should be allowed to reach the same ambient temperature, with consistent grip and orientation. The error figures from changing the orientation of a large instrument do not carry over directly to a micrometer for small watch components. How an instrument is supported still affects the measurement. 6
Agreement at zero alone does not establish accuracy across the range. Modern inspection sets the reference and then compares indications at several positions using standards of known dimensions, such as gauge blocks. 6
In everyday use the measuring faces should be clear of chips and dust, readings should avoid parallax and any constant-force device should be used correctly. Cleaning, checking the screw, preventing rust and protecting the instrument from shocks in storage help keep it capable of measuring. Palmer’s way of reading a screw depends on precise construction and continued inspection to work as a practical measuring instrument. 6
What survives in modern instruments#
Today, analogue scales are joined by digital displays and measurement outputs, with specialised faces such as blades, spherical contacts and contacts for measuring screws. These developments reduce reading errors and improve contact with specific shapes. Temperature, contact force, face geometry and setting the reference still matter with digital tools that measure between opposing faces. 6
In horology the Palmer design made screw displacement easy to read as a number and helped makers produce and inspect mainsprings and pinions. It gave them a common tool for comparing dimensions and using the results to guide manufacturing and inspection. 1 5 6
Timeline#
| Date | Event and limits of the evidence |
|---|---|
| Seventeenth century | Gascoigne uses a screw in astronomical measurement, a distinct application from a portable outside micrometer. 4 |
| Late eighteenth to early nineteenth century | Bench measuring instruments by Watt, Maudslay and others precede Palmer’s design. 4 |
| 7 September 1848 | Palmer patent. The museum record and 1900 retrospective exhibition report give the same date. 2 3 |
| 19 December 1849 | Alcan’s report is approved at a meeting of the society. 1 |
| 1850 | The bulletin publishes the 1 mm pitch, 20-division gauge and its use for measuring sheet thickness. 1 |
| 1855 | Karmarsch reports on the construction and measurements of a tool signed Palmer and deformation of paper under contact. Reprinted from an 1854 publication. 9 |
| August 1867 | Brown and Sharpe encounter the Palmer type in Paris, according to Roe’s history. 2 |
| 1868–1869 | Market introduction and catalogue listing of the small sheet-metal gauge. Later histories describe the commercial dates differently. 2 4 |
| 1877 | A Brown & Sharpe one-inch model appears in the catalogue. 2 |
| 1894 | The expanded American manual for watchmakers describes measuring mainsprings and pinions and how to read the 40 threads-per-inch type. 5 |
| 1900 | The retrospective exhibition report for the Paris Exposition reproduces Palmer’s patent drawing. 3 |
| Verified in 2026 | Public technical material describes analogue and digital models, specialised faces and practices for constant force, temperature and calibration. 6 |
Sources for the design and its adoption#
The museum and retrospective exhibition records were consulted to identify the patent. Roe’s history of tools and other works cover the American products. The 1850 report gives construction details, and the 1894 manual describes the micrometer’s uses for watchmakers. 1 2 3 5 7
References#
- Alcan, “Rapport … sur la fabrication des tubes sans soudure, emboutis, par M. Palmer”, Bulletin de la Société d’encouragement pour l’industrie nationale, year 49, 1850, pp. 28–31 (measuring instrument on pp. 30–31, plate 1126). Full text, CNAM Cnum. Accessed 6 November 2026.
2. Joseph Wickham Roe, English and American Tool Builders, 1916 (edition consulted 1926), pp. 211–213 and fig. 44. Full text, Project Gutenberg. A later history of tools quoting an 1892 letter from Lucian Sharpe. Accessed 6 November 2026. For the number and title of the patent, see also the Science Museum Group record for Palmer.
3. Musée rétrospectif des classes 19, 20, 21, 22 : mécanique … à l’exposition universelle internationale de 1900, à Paris : rapport du comité d’installation, p. 85, “Palmer — Calibre à vis et vernier circulaire”. Full text, CNAM Cnum. Reproduces plate 46 from the 1847–1849 patent publications. For the discrepancy in patent numbers, see the Science Museum Group drawing record 1960-34. Accessed 6 November 2026.
4. Mitutoyo, The History of the Evolution of the Micrometer, catalogue no. 257(4), updated May 2018, pp. 3–6. Official PDF. Manufacturer’s historical overview. Accessed 6 November 2026.
5. Claudius Saunier, The Watchmakers’ Hand Book, Illustrated American Edition, revised and enlarged by Henry G. Abbott, Geo. K. Hazlitt & Co., 1894, §310, pp. 270–271, fig. 135. Full text, Project Gutenberg. Accessed 6 November 2026.
6. Mitutoyo, Quick Guide to Measurement, catalogue E11003, PDF updated in 2024, printed pages PG06–13. Official PDF. Construction, reading, contact deformation, temperature, inspection of measuring faces and precautions during use. Accessed 6 November 2026.
7. Science Museum Group, “Palmer’s micrometer (replica)”, object 1928-1120. Collection record. Manufacturing date, range and scale of the replica. Accessed 6 November 2026.
8. Office québécois de la langue française, “Palmer”, Grand dictionnaire terminologique, L. Roucoules, 1977. Terminology record. Accessed 6 November 2026.
9. Karl Karmarsch, “Beschreibung zweier Blech-Lehren mit Mikrometerschraube, nebst Untersuchungen über deren Brauchbarkeit zum Messen der Papierdicken”, Polytechnisches Journal, vol. 135, 1855, article XL, p. 178 ff., plate III. Reprinted from Mittheilungen des hannoverschen Gewerbe-Vereins, part 3, 1854. Digital edition, Berlin-Brandenburgische Akademie der Wissenschaften. Accessed 6 November 2026.