This article was translated from Japanese using AI. Read the Japanese original
From waiting for a star to tracking it#
The Repsold self-registering micrometer is an eyepiece instrument for a transit telescope or transit circle. The observer aligns a moving wire with the star image, and the instrument electrically records when the wire passes predetermined positions. It is also called an impersonal micrometer, while traveling-wire micrometer includes later developments. Here, a micrometer is an instrument that uses a precision screw to measure the position of an image in a telescope. 1 2
Its connection with clocks is in observations used to determine clock corrections. With a fixed wire, observers judged when a star crossed the wire and pressed a key at that moment. Differences in judgement and action introduced an observer-specific bias known as the personal equation (article in Japanese). The self-registering method changes the observer’s task from reacting at an instant to continually aligning a star and wire. 1 2
Screw, moving wire, contacts and recorder#
Automatic recording with manual tracking#
The observer turns a screw at the eyepiece, tracking the star image across the field with the moving wire. Contacts that turn with the screw produce electrical signals at known positions and send them to a chronograph. The record gives the time corresponding to the position of the wire aligned with the star. Any misalignment between the wire and the star therefore affects the observation. 1 2
Gill also considered it important for the screw to move both the wire and the eyepiece. When tracked together in this way, the star and wire appear almost stationary to the observer. Moving the wire alone gives a different view of the motion. 1
Self-registering describes the recording, and the drive may be manual. The six-inch transit circle used at the US Naval Observatory from 1911 to 1918 had a manually operated Repsold-type instrument made by Warner & Swasey. According to Hammond, observers followed the star with a closely spaced pair of wires. They used a reversing prism in front of the eyepiece in two positions to reduce errors associated with the way they bisected the star image and the direction of motion. 3
Assistance from clockwork#
To reduce the work of continuously turning the screw, a clockwork drive was introduced to provide most of the movement, leaving the observer to correct the tracking. Gill describes reports by H. Struve in 1901 and by Fritz Cohn later. A friction drive adjusted the speed of the screw by changing where a disc pressed against a cone rotating at constant speed. Stars move across the field at different speeds depending on their declination, so a single fixed speed would be insufficient. 1
Even with a motorised drive, observers still needed to check the reference time, the telescope’s orientation and the alignment of wire and star. 1 2
How accuracy was checked#
Hammond used a test apparatus that moved an artificial star. He compared an automatic reference record from the artificial-star apparatus with the record made by tracking it in the usual way. The test measured absolute personal error in addition to agreement between observers. He also compared these results with relative differences derived from observations of real clock stars. 3
The results show that corrections remained with the self-registering method. For example, the relative corrections from clock stars to bring Frederickson, Rines, Wylie and Aston onto Hammond’s system were −0.007, −0.021, +0.005 and +0.005 seconds respectively. These values came from the same instrument and series of observations. For slow stars near the pole, the artificial-star tests gave weaker determinations, and Hammond was cautious in his interpretation. 3
In 1944 Watts likewise reported that Repsold’s manual method greatly reduced personal equation while still leaving some residual error. 2
From motor drive to a different way of recording#
One problem Watts addressed was that the required tracking speeds near the celestial equator and at a declination of about 89 degrees were in a ratio of about 1 to 0.017. In 1929 he began testing a small synchronous motor to drive the screw directly. Speed was varied by changing the supply frequency, with brief frequency corrections to keep the wire aligned with the star. He reported that the method was adopted on the six-inch transit circle in 1933 and on the nine-inch instrument in 1936. 2
The earlier method recorded when the wire passed a specified position, so slowly moving stars produced longer intervals between signals. From 1938 Watts tested the reverse method, photographing the scale on the screw head at times determined by a reference clock. This changed the method from obtaining time from position to reading position at predetermined times. In 1940 the source of the drive frequency was also replaced with an electronic oscillator. These developments brought together mechanical design, electrical control and photographic recording. 2
Development and significance#
Gill associates Repsold’s proposal with issue 2940 of Astronomische Nachrichten and the detailed descriptions of two designs with issue 3377. Watts dates the development of the practical form to 1889–1895. The instrument developed from proposal to detailed design and adoption in observatories. 1 2
Its historical significance lies in rearranging the measurement around continuous tracking, contacts at known positions and timed recording, then testing the remaining errors experimentally. 1 2 3
Chronology#
| Date | Event |
|---|---|
| 1889–1895 | Watts dates the development of the practical Repsold design to this period. 2 |
| March 1901 | Gill records Struve’s report on clockwork assistance. 1 |
| 1911–1918 | A manual Repsold-type instrument is used with the US Naval Observatory’s six-inch transit circle. 3 |
| 20 May 1921 | Hammond publishes his tests and observations on personal error. 3 |
| 1929 | Watts starts testing a synchronous-motor drive. 2 |
| 1933 and 1936 | Motor drive is adopted on the US Naval Observatory’s six-inch and nine-inch transit circles. 2 |
| 1938 | Watts starts testing photography of the scale at predetermined times. 2 |
| 1940 | An electronic oscillator replaces the generator supplying the drive frequency. 2 |
| 1944 | Watts publishes his experiments on the drive and recording methods. 2 |
References#
- David Gill, “Micrometer”, Encyclopædia Britannica, 1911 edition, sections on self-registering instruments and clockwork. Accessed 13 November 2026.
- C. B. Watts, “Experiments in the Design of the Traveling-Wire Micrometer”, The Astronomical Journal, vol. 50, 1944, pp. 179–182. Accessed 13 November 2026.
- J. C. Hammond, “Personal Errors in the Use of a Self-Registering Micrometer”, The Astronomical Journal, vol. 33, 20 May 1921, pp. 155–157. Accessed 13 November 2026.