This article was translated from Japanese using AI. Read the Japanese original
Why the end of a balance spring is shaped#
A terminal curve, courbe terminale or courbe extrême in French, is a shape given to the end of the spring regulating the balance. The inner end is attached to a collet that turns with the balance, and the outer end to a fixed stud. Constraining the two ends affects deformation throughout the coils. Shaping a terminal limits movement of the centre about which the spring expands and contracts away from the balance axis and reduces lateral forces on the staff. Its purpose goes beyond making the spring reach a point of attachment. 1
A Breguet overcoil raises the outer coil to a higher plane. Phillips curves are a family of curves derived from theoretical conditions. Terminal curve is the broader term for these kinds of end designs. A cylindrical balance spring can have curves at both its upper and lower ends. A flat spring can have a corrective shape at its inner end. Modern micromachining also allows designs that vary width and stiffness within a single plane. 1 4 5
Origins and theory#
Breguet’s overcoil#
The Breguet company history dates Abraham-Louis Breguet’s introduction of an outer coil raised and bent inwards to 1795. Lifting the coil approaching the outer end out of its normal plane allows the attachment to sit farther in without interfering with the coils below. The company links this arrangement to concentric expansion and contraction, greater accuracy and reduced balance-staff wear. The date comes from the company’s historical account. 2
The effects of the spring ends had been recognised before Breguet’s design. In the opening of his 1860 paper, Édouard Phillips credits Pierre Le Roy with finding that choosing the ends could help achieve isochronism. Phillips’s work recast an adjustment familiar in practice as a problem in the motion of an elastic body and a balance. 1
Phillips’s 1860 paper#
“Mémoire sur le spiral réglant des chronomètres et des montres” appeared in the second series of the Journal de mathématiques pures et appliquées, volume 5, 1860, pp. 313–366. A note at the start records the committee’s report, read to the Academy of Sciences on 28 May 1860. The CNAM catalogue also has an 1861 entry for a study under the same title. 1 7
The paper derives the restoring moment when the balance deforms the spring with its constrained ends through a given angle. It shows that the position of the spring’s centre of mass and the forces on the staff enter the relationship. Keeping the centre of mass near the axis and reducing lateral reactions helps achieve isochronism, when the time per complete oscillation stays the same as amplitude changes. Phillips used a graphical construction to find curves satisfying the conditions and checked the centre of the coils after deformation. The method allows several shapes. 1
Theory and a watchmaker’s objections#
A Practical Treatise on the Balance Spring, published in 1876 under the name “Excelsior”, recognises Phillips as an authority on theory and discusses how to form the curves in practice. The author questioned the weight given to the curve’s centre of mass and to the direction of the tangent at the end, and proposed his own constructions and running tests. The book documents a debate about ideal conditions, poise after attachment, and the forming and testing possible in a repair workshop. It does not establish an error in Phillips’s theory. 3
Mechanism and mechanics#
Concentric breathing#
When the balance turns one way, the coils tighten. When it turns the other way, they open. Watchmakers call this motion breathing. If the outer end attaches directly along the continuation of a normal spiral, the spring tends to pull to one side towards its attachment. Changing the curvature, length and orientation of the fixed end can distribute the deformation due to that constraint across the coils. 1 6
Movement of the centre of mass away from the axis can change the effect of gravity with position and affect the lateral forces the bearings carry during oscillation. If the spacing of the coils varies enough for adjacent coils to touch, the spring’s effective behaviour can change suddenly. A modern patent on terminal design also discusses concentricity in relation to bearing friction, nonlinearity and coil collisions. 5
An idealised model of isochronism#
The restoring moment and equation of motion discussed by Phillips on pp. 318–320 give the following idealised model in modern notation. 1
\[ I\ddot{\theta}+k\theta=0,\qquad T=2\pi\sqrt{\frac{I}{k}} \]I is the balance’s moment of inertia about its axis (kg·m²), θ is its angle from equilibrium (rad), k is the torsional spring constant (N·m/rad), and T is the period of a complete oscillation (s). If the restoring torque is proportional to the angle and I and k are constant, the period is independent of amplitude. Phillips sometimes uses the time of a half-oscillation. Here the period is explicitly for a complete oscillation.
The model omits escapement impulses, air resistance, bearing friction, spring inertia, gravity and temperature changes. A terminal curve principally addresses geometry and boundary conditions, while these influences still affect operation. On pp. 343–344 Phillips says that oil, the escapement and air cannot all be included in the theory, and that practical isochronism also requires choosing a suitable spring length. 1
Differences by construction#
| Design | Treatment of the terminal | Design and implementation |
|---|---|---|
| Cylindrical balance spring | Curves at the upper and lower ends | Design relates the two ends to the cylindrical coils and requires height |
| Breguet overcoil | Outer coil rises and curves inwards | Requires suitable height, parallelism and clearance above the coils below |
| Inner-terminal correction | Shape changes near the collet | Addresses the inner constraint separately from work at the outer end |
| Stiffness correction in one plane | Width or cross-section changes at the outer coil | Saves height and uses micromachining and numerical design to adjust concentricity |
The historical descriptions of cylindrical springs and overcoils draw on 1 3. For the inner-terminal correction and silicon construction see 4, and for in-plane stiffness correction see 5.
Materials, manufacture and adjustment#
For a metallic terminal curve, care is needed to keep the spring flat while shaping the end, keep the raised coil parallel to the body and let the end reach its intended position naturally once attached. The 1876 treatise discusses paper or metal gauges, tweezers and forming tools, as well as springback on heating and effects on temper. These processes pertain to the steel springs of the period. Modern alloys and silicon have their own processing requirements. 3
In a 2018 report, maker Peter Elliot Glomb describes forming two bends and a terminal on an off-the-shelf Nivarox spring for a commissioned Dornblüth watch, pinning the spring to the collet and stud and adjusting the frequency. He forms the curve to suit the positions of the stud and regulator and checks flatness, centring and concentric breathing. Excessive bending can harm the material and rate, so he finishes with dynamic poising tests in several positions. The curve’s appearance is only one part of the job. 6
Silicon cannot be plastically bent like metal. US8425110B2 describes making the spring body and collet as one integral piece and the elevated terminal as a separate integral piece, joined by a post and recess. It includes shaping by deep reactive ion etching (DRIE), the oxide layer and the joining process. The patent documents manufacturable designs. The extent to which the listed variants went into series production requires separate evidence. 4
Evaluating performance and its limits#
Evaluation combines observing concentricity with comparing rates at different amplitudes after winding and as the spring unwinds, in dial-up, dial-down and vertical positions. Setting the mean rate and reducing its variation with amplitude are separate adjustments. The 1876 treatise distinguishes the two and advises allowing the spring to settle after reshaping the curve before testing. 3
The modern EP2687917B1 patent describes numerically optimising the spring cross-section using objectives such as the reaction force at the fixed stud and movement of the centre of mass throughout the working amplitude range. It evaluates the spring throughout its motion, as well as its shape at rest. 5
Magnetic resistance and thermal behaviour also depend on the materials and the movement. Relevant factors include thermoelastic compensation with silicon and its oxide layer, the alloy chosen, changes in balance inertia, and the condition of the bearings and escapement. 4 5
Timeline#
| Period | Documented development |
|---|---|
| Eighteenth century | Phillips identifies Le Roy’s work on selecting the ends and isochronism as a precedent 1 |
| 1795 | Date Breguet gives for introducing the overcoil 2 |
| May and September 1860 | Committee report on Phillips’s paper and publication in the mathematics journal 1 |
| 1861 | Publication of a study under the same title in the CNAM catalogue 7 |
| 1876 | Excelsior’s treatise details layout, forming, adjustment during running and objections to the theory 3 |
| 2006 | According to Breguet, it introduces a silicon balance spring and escapement in a watch 2 |
| 15 December 2008 | Priority date of the patent for a silicon overcoil assembled from two parts 4 |
| April 2018 | A maker reports on forming a metal terminal by hand and adjusting it in different positions 6 |
| 28 May 2025 | Grant publication EP2687917B1, covering optimisation of the cross-section over a range of motion 5 |
Limits of interpretation#
A terminal curve is a design concept spanning several periods and constructions, so there is no single patent or first production watch for the whole category. The historical attribution to 1795, the theory of 1860 and recent patents for materials and manufacturing concern different stages. Phillips’s paper makes important use of a cylindrical spring as a model. Extending its conditions to a given flat spring requires checking how the models correspond. For a watch without drawings or test records, a photograph of the terminal shape alone cannot establish that it meets the theory.
References#
- E. Phillips, Mémoire sur le spiral réglant des chronomètres et des montres, 1860, Journal de mathématiques pures et appliquées, 2e série, 5, pp. 313–366, especially pp. 313–320 and 321–347. Open text at NUMDAM. Accessed 13 October 2026.
2. Montres Breguet, Invention du « spiral Breguet », official history covering 1795, undated. French text. Accessed 13 October 2026.
3. “Excelsior”, A Practical Treatise on the Balance Spring, D. H. Hopkinson, New York, 1876, pp. 75–91, §§141–179. Open scan. Accessed 13 October 2026.
4. Montres Breguet SA, Breguet overcoil balance spring made of silicon-based material, US8425110B2, 23 April 2013, priority 15 December 2008. Description, figs. 1–10 and claims 1, 12 and 13. Patent text. Accessed 13 October 2026.
5. Hairspring for a timepiece and hairspring design for concentricity, EP2687917B1, 28 May 2025. Background, Summary and portions of the Description on optimisation and micromachining. Patent text. Accessed 13 October 2026.
6. Peter Elliot Glomb, “Making a Balance Complete with Breguet Overcoil”, Horological Times, April 2018, pp. 20–26. PDF published by AWCI. Accessed 13 October 2026.
7. CNAM / Bibale, Mémoire sur le spiral réglant des chronomètres et des montres / Phillips, bibliographic record for 1861. Catalogue entry. Accessed 13 October 2026.